Drug concentration at the reservoir is assumed to be 1kmol/m3 an

Drug concentration at the reservoir is assumed to be 1kmol/m3 and drug concentration at the outlet to be 0kmol/m3. This concentration represents drug concentration in the eye. Drug diffusivity is assumed to be the same as the synthetic corticosteroid fluocinolone acetonide in deionized (DI) water (2.3 × 10−7cm2/s) [8]. Figure 3 Schematic illustration of present check details device.

Figure 4 Various microchannels Inhibitors,research,lifescience,medical patterns considered for design analysis and simulation. Simulation results of drug diffusion within the microchannels as a function of time and drug diffusion from the drug reservoir revealed high-concentration areas to zero drug concentration areas in the vitreous body. Since Inhibitors,research,lifescience,medical drug consumption occurred at the blood vessel of a vitreous body which can be approximated as zero, the amount of diffusion may vary with the concentration gradient, however, a constant drug release rate can be obtained. 2.4. Fabrication Master molds for both upper and bottom Inhibitors,research,lifescience,medical layers of the reservoir are made of Acura 50 plastic (3D system corp.) and constructed from 3D stereolithography process using 3D Viper SLA system (3D system corp.). PDMS [11] is mixed silicone elastomeric

base and a curing agent with a 10:1 ratio (SYLGARD 184, DOW CORNING) and poured into the master molds. The PDMS is degassed in a vacuum machine for 20 minutes (Durable medical equipment Inc., Richmond, VA) and cured at room temperature for 24 hours or 80°C for 2 hours. The microchannel geometries will be formed using soft lithography on the 4′′ silicon wafers after baking at 1000°C for at least 10 hours to get at least 1μm thickness Inhibitors,research,lifescience,medical of an oxides layer. The wafers are vapor coated with hexamethyldisilazane

(HMDS) adhesion promoter. After the mask is completed, photoresist (AZ ECI #3012, AZ Electronic Materials, Branchburg, NJ, USA) is poured on the wafer around 2.5mL and spin coated at 4000rpm for 30s (expected thickness less than 0.8μm layer), and then the wafer Inhibitors,research,lifescience,medical is baked at 90°C for 1 minute. After exposure, native oxide is removed with a 20% KOH solution dip at 80°C for 2 hours and 5 hours so that 100 and 250μm etch depths for the microchannels will be achieved. The final step of the wafer fabrication many is to remove the oxide by using a BOE etch. Lastly, the assorted microchannels will be assembled to the PDMS reservoir and sealed using the O2 plasma etching processes in accordance with 600mTorr pressure and 20W power for 35s. 3. Results and Discussion Several simulations of drug diffusion rates from various microchannel configurations were carried out. The result of diffusion rate through typical straight microchannels is shown in Figure 5. The length and width of the straight microchannel for this simulation are 8mm and 500μm.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>